Reliable ventilation begins with determining the required supply and exhaust air quantities. We take into account the heat output from compressors, dryers and other components as well as the spatial and operational conditions of the system.
On this basis, we plan air ducts, supply and exhaust air openings, fans and the necessary ventilation flaps. All components are coordinated with each other and integrated into the overall concept during the 3D planning.
Supply, exhaust and recirculation airflow
A coordinated air flow ensures that the required fresh air reaches the system reliably and the resulting waste heat is dissipated in a controlled manner. We plan supply, exhaust and recirculated air according to the heat development, the spatial conditions and the requirements of the components used.
The supply air supplies the system with sufficient outside air, while the exhaust air specifically removes heated air from the system area. If necessary, a recirculating air duct can also be provided in order to distribute air flows within the system in a targeted manner and to optimally supply different operating areas.
The coordinated positioning of air openings, ducts and other ventilation components creates defined air paths and an even flow through the system
Fan design
The exhaust fans are designed according to the required air volume flow and ensure the targeted removal of heated air from the system. At the same time, it must be ensured that a sufficient amount of outside air can flow in via the intended supply air areas.
When designing, we take into account the pressure losses of the filter packages, ventilation ducts, weather protection grilles and other components in the air path. On this basis, it is checked whether the required supply air can be provided without additional support.
If there are higher pressure losses or large amounts of air required, additional supply air fans can be used. In this way, supply and exhaust air are coordinated and the necessary air exchange within the system is ensured.
Positioning of supply and exhaust air
The position of supply and exhaust air openings is specifically taken into account when planning the system. We make sure that heated exhaust air is not immediately sucked in again via the supply air and that no undesirable air circuits form.
The arrangement of compressors, dryers, heat-generating control cabinets and other system components is also included in the air flow. In this way, fresh air can be directed specifically to the relevant areas and heated air can be removed from the station as directly as possible.
Customer specifications regarding the position of supply and exhaust air are also taken into account and integrated into the ventilation concept, taking into account the required air volumes and technical framework conditions.
Exhaust air ducting from adsorption dryers
With adsorption dryers, the warm and moist exhaust air generated during regeneration must be reliably removed from the system area. For this purpose, we plan separate exhaust air ducts that are tailored to the technical requirements of the respective dryer and the spatial conditions.
Depending on the system concept, the exhaust air can be guided specifically to the intended exit point via appropriately sized spiral folded pipes. We take into account the air volume, cable routing and required cross-sections as well as the dryer manufacturer's specifications.
The exhaust air routing is already taken into account in the 3D planning and coordinated with pipes, cable routes and other system components.